Verified product catalogue
Choose a product
56 products match
BFC-000124
Ductile Iron Gate Valve – Flanged PN16 – Soft Seated
Ductile Iron · PN16 · PN16
Price: On Application
BFC-000159
Cast Iron Gate Valve – Flanged PN16 – Stainless Steel Stem – PN16 Rated
Cast Iron · PN16 · PN16, PN10
Price: On Application
BFC-000167
CR Brass Gate Valve
Brass · Compression Ends · 15mm, 22mm, 28mm, 35mm, 42mm, 54mm
Price: On Application
BFC-000173
Ductile Iron Gate Valve – Flanged PN16 – Soft Seated – NBR
Ductile Iron · PN16 · PN16
Price: On Application
BFC-000180
Brass Vacuum Tanker Gate Valve – AGRI Square Flanged
Brass · AGRI Standard Square · 3 Bar, 2.5 Bar, 1.5 Bar
Price: On Application
BFC-000210
Brass Lockshield Gate Valve
Brass · Compression Ends · 15mm, 22mm, 28mm
Price: On Application
BFC-000213
Stainless Steel Gate Valve – Flanged PN16
Stainless Steel · PN16 · PN16
Price: On Application
BFC-000241
Forged Steel Gate Valve – Socket Weld
Forged Steel · Socket Weld · Class 800, 136.2 Bar
Price: On Application
BFC-000248
Cast Iron Gate Valve – Flanged Table E
Ductile Iron · Table E · 13.8 Bar
Price: On Application
BFC-000261
Cast Iron Gate Valve – Flanged PN16 – Brass Stem – PN10 Rated
Cast Iron · PN16 · PN16, PN10
Price: On Application
BFC-000276
Ductile Iron Gate Valve – Flanged PN16 – BS5163 Part 1 & 2:2004 – WRAS Approved
Ductile Iron · PN16 · PN16
Price: On Application
BFC-000277
Ductile Iron Gate Valve – Flanged PN16 – BS5150 (EN1171)
Ductile Iron · PN16 · PN16
Price: On Application
BFC-000282
Forged Steel Gate Valve – Flanged ANSI 150
Forged Steel · ANSI 150 · ANSI 150
Price: On Application
BFC-000284
Ductile Iron Gate Valve – BSI V7 Gas Approved – PN7 Rated
Ductile Iron · PN16 · PN7, PN16, 7 Bar
Price: On Application
BFC-000292
Brass Lockshield Gate Valve – PN20 – WRAS Approved
Brass · BSPT · PN20
Price: On Application
Technical overview and selection guidance
A gate moves linearly out of the flow path for isolation. These valves are generally selected for fully open or fully closed duty rather than routine throttling.
Where Resilient Seated Gate Valves fit
Resilient Seated Gate Valves may be considered where its operating principle, envelope and materials suit the process. Confirm whether the duty is isolation, throttling, diversion, non-return or pressure control; a familiar valve type is not automatically the lowest-risk choice.
Selection checklist
| Factor | What to confirm |
|---|---|
| Process medium | Composition, concentration, solids, viscosity, toxicity and cleaning regime. |
| Pressure and temperature | Normal, design, transient and vacuum conditions against the manufacturer curve. |
| Materials | Body, trim, seat, seals, fasteners and coatings—not body material alone. |
| Connections | Nominal size, bore, flange or thread standard, face-to-face and installation space. |
| Operation | Manual or actuated, cycle rate, closing time, fail action, feedback and utilities. |
| Compliance | Project specification, testing, water, fire-safe or hazardous-area requirements. |
Common specification mistakes
- Quoting only nominal size and pressure class.
- Assuming a material name proves chemical compatibility.
- Ignoring transient pressure, differential pressure or installation orientation.
- Selecting an actuator from running torque alone.
- Treating an approval held by one product variant as applying to the whole range.
Frequently asked questions
Can one pressure rating be applied to every Resilient Seated Gate Valves?
No. The allowable pressure changes with materials, temperature, design, size and the governing standard. Use the current product pressure-temperature table.
What information is needed for automation?